  scas062a ? july 1987 ? revised april 1993 copyright ? 1993, texas instruments incorporated 1 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77251?1443 ? flow-through architecture optimizes pcb layout ? center-pin v cc and gnd configurations minimize high-speed switching noise ? epic ? (enhanced-performance implanted cmos) 1- m process ? 500-ma typical latch-up immunity at 125 c ? package options include plastic small-outline packages, and standard plastic 300-mil dips description this octal bus transceiver is designed for asynchronous communication between data buses. the control function implementation allows for maximum flexibility in timing. these devices transmit data from the a bus to the b bus or from the b bus to the a bus depending upon the level at the output-enable (oeab or oeba ) inputs. the output-enable inputs can be used to disable the device so that the buses are effectively isolated. the dual-enable configuration gives these devices the capability to store data by simultaneous enabling of oeab and oeba . each output reinforces its input in this transceiver configuration. thus, when both control inputs are enabled and all other data sources to the two sets of bus lines are at high impedance, both sets of bus lines (16 in all) will remain at their last states. the 8-bit codes appearing on the two sets of buses will be complementary for the 74ac11620. the 74ac11620 is characterized for operation from ? 40 c to 85 c. function table inputs operation oeba oeab operation l l b data to a bus h ha data to b bus h l isolation l h b data to a bus, a data to b bus dw or nt package (top view) 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 a1 a2 a3 a4 gnd gnd gnd gnd a5 a6 a7 a8 oeab b1 b2 b3 b4 v cc v cc b5 b6 b7 b8 oeba epic is a trademark of texas instruments incorporated.
scas062a ? july 1987 ? revised april 1993 2 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77251?1443 logic symbol ? logic diagram (positive logic) 2 a1 b1 en2 24 oeab 1 a1 2 a2 b1 23 3 a3 4 a4 9 a5 10 a6 11 a7 12 a8 b2 22 b3 21 b5 17 b4 20 b6 16 b8 14 b7 15 oeba 1 13 24 23 1 en1 13 oeba oeab to 7 other channels ? this symbol is in accordance with ansi/ieee std 91-1984 and iec publication 617-12. absolute maximum ratings over operating free-air temperature range (unless otherwise noted) ? supply voltage range, v cc ?0.5 v to 7 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . input voltage range, v i (see note 1) ?0.5 v to v cc + 0.5 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . output voltage range, v o (see note 1) ?0.5 v to v cc + 0.5 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . input clamp current, i ik (v i < 0 or v i > v cc ) 20 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . output clamp current, i ok (v o < 0 or v o > v cc ) 50 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous output current, i o (v o = 0 to v cc ) 50 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous current through v cc or gnd pins 200 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . storage temperature range ?  65 c to 150 c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ? stresses beyond those listed under ?absolute maximum ratings? may cause permanent damage to the device. these are stress ratings only, a nd functional operation of the device at these or any other conditions beyond those indicated under ?recommended operating conditi ons? is not implied. exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. note 1: the input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
scas062a ? july 1987 ? revised april 1993 3 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77251?1443 recommended operating conditions min nom max unit v cc supply voltage 3 5 5.5 v v cc = 3 v 2.1 v ih high-level input voltage v cc = 4.5 v 3.15 v v ih high-level input voltage v cc = 5.5 v 3.85 v v cc = 3 v 0.9 v il low-level input voltage v cc = 4.5 v 1.35 v v il low-level input voltage v cc = 5.5 v 1.65 v v i input voltage 0 v cc v v o output voltage 0 v cc v v cc = 3 v ?4 i oh high-level output current v cc = 4.5 v ?24 ma i oh high-level output current v cc = 5.5 v ?24 ma v cc = 3 v 12 i ol low-level output current v cc = 4.5 v 24 ma i ol low-level output current v cc = 5.5 v 24 ma ? t/ ? v input transition rise or fall rate oeba or oeab 0 5 ns/v ? t/ ? v input transition rise or fall rate a or b 0 10 ns/v t a operating free-air temperature ?40 85 c
scas062a ? july 1987 ? revised april 1993 4 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77251?1443 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) parameter test conditions v cc t a = 25 c min max unit parameter test conditions v cc min typ max min max unit 3 v 2.9 2.9 i oh = ? 50 a 4.5 v 4.4 4.4 i oh = ? 50 a 5.5 v 5.4 5.4 v oh i oh = ? 4 ma 3 v 2.58 2.48 v v oh i oh = ? 24 ma 4.5 v 3.94 3.8 v i oh = ? 24 ma 5.5 v 4.94 4.8 i oh = ? 75 ma ? 5.5 v 3.85 3 v 0.1 0.1 i ol = 50 a 4.5 v 0.1 0.1 i ol = 50 a 5.5 v 0.1 0.1 v ol i ol = 12 ma 3 v 0.36 0.44 v v ol i ol = 24 ma 4.5 v 0.36 0.44 v i ol = 24 ma 5.5 v 0.36 0.44 i ol = 75 ma ? 5.5 v 1.65 i i oeba or oeab v i = v cc or gnd 5.5 v 0.1 1 a i oz ? a or b ports v o = v cc or gnd 5.5 v 0.5 5 a i cc v i = v cc or gnd, i o = 0 5.5 v 8 80 a c i oeba or oeab v i = v cc or gnd 5 v 4 pf c io a or b ports v o = v cc or gnd 5 v 12 pf ? not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. ? for i/o ports, the parameter i oz includes the input leakage current. switching characteristics over recommended operating free-air temperature range, v cc = 3.3 v 0.3 v (unless otherwise noted) (see figure 1) parameter from to t a = 25 c min max unit parameter from (input) to (output) min typ max min max unit t plh a or b b or a 1.5 6.8 9 1.5 10.2 ns t phl a or b b or a 1.5 6.5 8.2 1.5 9.1 ns t pzh oeba a 1.5 8 10.3 1.5 11.7 ns t pzl oeba a 1.5 7.3 9.8 1.5 10.9 ns t phz oeba a 1.5 6.7 8.4 1.5 9 ns t plz oeba a 1.5 7.8 9.6 1.5 10.4 ns t pzh oeab b 1.5 8.4 10 1.5 11.5 ns t pzl oeab b 1.5 8.1 10.1 1.5 11.3 ns t phz oeab b 1.5 7 8.7 1.5 9.4 ns t plz oeab b 1.5 7.7 9.6 1.5 10.4 ns
scas062a ? july 1987 ? revised april 1993 5 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77251?1443 switching characteristics over recommended operating free-air temperature range, v cc = 5 v 0.5 v (unless otherwise noted) (see figure 1) parameter from to t a = 25 c min max unit parameter from (input) to (output) min typ max min max unit t plh a or b b or a 1.5 5.2 6.6 1.5 7.4 ns t phl a or b b or a 1.5 4.8 6.3 1.5 7.1 ns t pzh oeba a 1.5 6 7.8 1.5 8.9 ns t pzl oeba a 1.5 5.5 7.6 1.5 8.5 ns t phz oeba a 1.5 5.9 7.5 1.5 8.1 ns t plz oeba a 1.5 6.3 8.1 1.5 8.7 ns t pzh oeab b 1.5 6.2 7.7 1.5 8.8 ns t pzl oeab b 1.5 6 7.8 1.5 8.8 ns t phz oeab b 1.5 6.1 7.7 1.5 8.2 ns t plz oeab b 1.5 6.2 7.9 1.5 8.6 ns operating characteristics, v cc = 5 v, t a = 25 c parameter test conditions typ unit c pd power dissipation capacitance per transceiver outputs enabled c l = 50 pf, f = 1 mhz 54 pf c pd power dissipation capacitance per transceiver outputs disabled c l = 50 pf, f = 1 mhz 11 pf
scas062a ? july 1987 ? revised april 1993 6 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77251?1443 parameter measurement information from output under test c l = 50 pf load circuit for outputs s1 2 v cc open gnd 500 ? 500 ? test t plh /t phl t plz /t pzl t phz /t pzh s1 open 2 v cc gnd output control (low-level enabling) output waveform 1 s1 at 2 v cc (see note c) output waveform 2 s1 at gnd (see note c) v ol v oh t pzl t pzh t plz t phz 50% 50% v c c 0 v 50% v cc 0 v v cc (see note a) 50% v cc 20% v cc 80% v cc t plh t phl 50% 50% 0 v 50% v cc 50% v cc v oh v ol input (see note b) output (see note d) voltage waveforms propagation delay times voltage waveforms enable and disable times v cc notes: a. c l includes probe and jig capacitance. b. all input pulses are supplied by generators having the following characteristics: prr 10 mhz, z o = 50 ? , t r 3 ns, t f 3 ns. for testing pulse duration: t r = t f = 1 to 3 ns. pulse polarity can be either high-to-low-to-high or low-to-high-to-low. c. waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. d. the outputs are measured one at a time with one transition per measurement. figure 1. load circuit and voltage waveforms
important notice texas instruments incorporated and its subsidiaries (ti) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. all products are sold subject to ti?s terms and conditions of sale supplied at the time of order acknowledgment. ti warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with ti?s standard warranty. testing and other quality control techniques are used to the extent ti deems necessary to support this warranty. except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. ti assumes no liability for applications assistance or customer product design. customers are responsible for their products and applications using ti components. to minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. ti does not warrant or represent that any license, either express or implied, is granted under any ti patent right, copyright, mask work right, or other ti intellectual property right relating to any combination, machine, or process in which ti products or services are used. information published by ti regarding third-party products or services does not constitute a license from ti to use such products or services or a warranty or endorsement thereof. use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from ti under the patents or other intellectual property of ti. reproduction of ti information in ti data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. reproduction of this information with alteration is an unfair and deceptive business practice. ti is not responsible or liable for such altered documentation. information of third parties may be subject to additional restrictions. resale of ti products or services with statements different from or beyond the parameters stated by ti for that product or service voids all express and any implied warranties for the associated ti product or service and is an unfair and deceptive business practice. ti is not responsible or liable for any such statements. ti products are not authorized for use in safety-critical applications (such as life support) where a failure of the ti product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of ti products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by ti. further, buyers must fully indemnify ti and its representatives against any damages arising out of the use of ti products in such safety-critical applications. ti products are neither designed nor intended for use in military/aerospace applications or environments unless the ti products are specifically designated by ti as military-grade or "enhanced plastic." only products designated by ti as military-grade meet military specifications. buyers acknowledge and agree that any such use of ti products which ti has not designated as military-grade is solely at the buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. ti products are neither designed nor intended for use in automotive applications or environments unless the specific ti products are designated by ti as compliant with iso/ts 16949 requirements. buyers acknowledge and agree that, if they use any non-designated products in automotive applications, ti will not be responsible for any failure to meet such requirements. following are urls where you can obtain information on other texas instruments products and application solutions: products applications amplifiers amplifier.ti.com audio www.ti.com/audio data converters dataconverter.ti.com automotive www.ti.com/automotive dlp? products www.dlp.com broadband www.ti.com/broadband dsp dsp.ti.com digital control www.ti.com/digitalcontrol clocks and timers www.ti.com/clocks medical www.ti.com/medical interface interface.ti.com military www.ti.com/military logic logic.ti.com optical networking www.ti.com/opticalnetwork power mgmt power.ti.com security www.ti.com/security microcontrollers microcontroller.ti.com telephony www.ti.com/telephony rfid www.ti-rfid.com video & imaging www.ti.com/video rf/if and zigbee? solutions www.ti.com/lprf wireless www.ti.com/wireless mailing address: texas instruments, post office box 655303, dallas, texas 75265 copyright ? 2009, texas instruments incorporated


▲Up To Search▲   

 
Price & Availability of 74AC11620DBLE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X